Rolled Steel Frame Motors

Features:
- Light weight
- Multiple mountings
- Large stocks

Standard
Mounting
Voltage
Enclosure
Motor type
Description
NEMA
 
 
Horizontal
LV
TEFC
 
AEGA  
AEGE EPACT
ODP
ASGA  
ASGANE  
Vertical
TEFC
 
AETA  
AETE EPACT
IEC, BS, AS, JIS, JEC, CNS Horizontal AEGF  
AEGL  
ODP
ASGF  
Vertical
TEFC
AETF  
AETL  


Type Code: AEGA / AETA

Low Voltage Rolled Steel Frame Motors, Design B
Output 1/3 ~ 2HP
Pole (Speed) 2 ~ 6
Voltage 230/460V (usable on 208V at 1.0 SF)
Frequency (Hz) 60
Frame Size A56C ~ C56C
Protection Enclosure TEFC, IP 44
Design Standards: NEMA MG-1, MG-13
Stator insulation: Class F Insulation, B rise SF 1.15.
Test procedure: ANSI/IEEE-112 Method B and full voltage measuring starting performance.


Type Code: ASGA
Low Voltage Rolled Steel Frame Motorse
Output 1/3 ~ 3HP
Pole (Speed) 2 ~ 6
Voltage 230/460V
Frequency (Hz) 60
Frame Size A56~B56
Protection Enclosure IP 22 Open, Drip-Proof
Design Standards: NEMA MG-1, MG-13
Environment: non-hazardous
Stator insulation: Class F Insulation, B rise SF 1.15


Type Code: AEGF
Low Voltage Rolled Steel Frame Motors
Output 1/4 ~ 3 HP
Pole (Speed) 2 ~ 6
Voltage 200 ~460
Frequency (Hz) 50, 60
Frame Size 63 ~ 90
Protection Enclosure IP 44


Type Code: AETF
Low Voltage Rolled Steel Frame Motors
Output 1/4 ~ 3 HP
Pole (Speed) 2 ~ 6
Voltage 200 ~460
Frequency (Hz) 50, 60
Frame Size 63 ~ 90L
Protection Enclosure IP 44


Type Code: ASGANE
Low Voltage Rolled Steel Frame Motors EPACT
Output 1-1/2 ~ 40HP
Pole (Speed) 2 ~ 6
Voltage 230/460V
Frequency (Hz) 60
Frame Size 143T~286TS
Protection Enclosure IP 22 Open, Drip-Proof
Design Standards: NEMA MG-1, MG-13
Environment: non-hazardous
Stator insulation: Class F Insulation, 80¢Jrise at SF 1.15


Type Code: AEGE /AETE
Low Voltage Rolled Steel Frame Motors EPACT, Design B
Output 1 ~ 2HP
Pole (Speed) 2 ~ 6
Voltage 230/460V (usable on 208V at 1.0 SF)
Frequency (Hz) 60
Frame Size 143C ~ 145C
Protection Enclosure TEFC, IP 44
Design Standards: NEMA MG-1, MG-13
Stator insulation: Class F Insulation, B rise SF 1.15.
Test procedure: ANSI/IEEE-112 Method B and full voltage measuring starting performance.


Type Code: AEGL
Standard 3-Phase High Efficiency Induction Motors
Low Voltage Rolled Steel Frame Motors
Output 1/2 ~ 2 HP
Pole (Speed) 2 ~ 6
Voltage 200 ~460
Frequency (Hz) 60
Frame Size 71 ~ 90
Protection Enclosure IP 44


Type Code: AETL
Standard 3-Phase High Efficiency Induction Motors
Low Voltage Rolled Steel Frame Motors
Output 1/2 ~ 2 HP
Pole (Speed) 2 ~ 6
Voltage 200 ~460
Frequency (Hz) 60
Frame Size 71 ~ 90
Protection Enclosure IP 44


Type Code: ASGF
Low Voltage Rolled Steel Frame Motors
Output 1/2 ~ 3 HP
Pole (Speed) 2 ~ 6
Voltage 200 ~460
Frequency (Hz) 50, 60
Frame Size 80 ~ 90L
Protection Enclosure IP 22


สนใจสินค้า หรือสอบถามรายละเอียดเพิ่มเติมได้ ที่